575 Business Park Lane
Allentown, PA 18109
Phone: 888-889-9787, 610-432-9787
Fax: 610-437-7030
E-mail: reliable@americanarch.com

navigation bar Site Map About Us Panel Testing Data Services Products List Custom Metal Roofing Residential Metal Roofing Commercial Metal Roofing Custom Fabrication Perimeter Edge Metals New! - Wind Design Calculator Home page ANSI/SPRI ES-1/ FM Approved Products

Panel Testing Data

Click on a test to go directly to it.

Project No. T109-03
Test Date 1/22/03
Ambient Temp. = 57.0 deg. F
Barometric Pressure = 30.11" Hg
ASTM E-1680-95
Air Leakage Test
Summary
Test Specimen Static Pressure Differential
(psf)
Air Leakage Rate
(cfm/lf)
Air Leakage Rate
(cfm/sf)
TL 1750 1-3/4" +1.57 0.002 0.001
High Integral Panel -1.57 0.009 0.006
24 GA x 18" w +6.24
-6.24
0.004
0.011
0.003
0.007

Project No. T109-03
Test Date 1/22/03
Panel Surface Temp. Prior to Test = 67 deg. F
Panel Surface Temp. During Test = 47 deg. F
Ponded Water Depth During Test = 1/2"
ASTM E-1646-95
Water Penetration Test
Summary
Test Specimen Static Pressure Differential
(psf)
Rate Test Duration Water Infiltration
TL 1750 1-3/4" 6.75 psf 5 gal./hr./sq. ft. 15 min. None
High Integral Panel 9.75 psf 5 gal./hr./sq. ft. 15 min. None
24 GA x 18" w 12.0 psf 5 gal./hr./sq. ft. 15 min. None

Return to the top.

Allowable Live Load Tables For American Architectural TL 1750 Roof Panel 22 GA

Allowable Live Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
22
GA
Steel
18
in.
1 326 247 171 125 96 75 61 50
2 202 131 91 67 51 40 32 26
3 234 151 106 78 59 46 37 31

Allowable Uplift Load Tables For American Architectural TL 1750 Roof Panel 22 GA

Allowable Uplift Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
22
GA
Steel
18
in.
1 284 182 127 94 73 58 47 39
2 332 266 219 164 127 102 83 69
3 363 291 207 153 118 94 77 64

Allowable Live Load Tables For American Architectural TL 1750 Roof Panel 24 GA

Allowable Live Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
24
GA
Steel
18
in.
1 197 158 131 97 74 58 47 39
2 155 100 70 51 39 31 25 20
3 179 116 81 59 45 36 29 23

Allowable Uplift Load Tables For American Architectural TL 1750 Roof Panel 24 GA

Allowable Uplift Load (psf)

Panel
Gage
Panel
Width
# of
Equal
Spans
Span (ft.)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
24
GA
Steel
18
in.
1 217 140 98 72 56 44 36 30
2 229 183 153 127 98 79 64 54
3 250 200 159 117 90 72 59 49